- Completed electrical and mechanical inspection on low voltage switchgear, troubleshooting and reporting issues.
- Inspect AC/DC switchgear, including QED2, QED6, and PZ4
- Examined relevant documents prior to inspections in order to become acquainted with property features.
- Completed thorough written descriptions and took photographs to document conditions.
- Read and interpreted electrical, mechanical, and architectural drawings and electrical code specifications for wiring layouts.
- Used testing instruments such as ohmmeters, voltmeters, ammeters, and multimeters.
- Inspected electrical systems, equipment and components to identify hazards, defects, and repair requirements.
- Installed, maintained, repaired, and tested equipment for electricity generation and utilization.
- Enhanced quality control by inspecting condition of equipment and tools.
- Use 5s procedures to maintain the surrounding area