Highly-motivated employee with desire to take on new challenges. Continuing to expand my knowledge in the Automation and I&E field. Having 2 years experience as a technician. Strong worth ethic, adaptability, hard working and exceptional interpersonal skills. Adept at working effectively unsupervised and quickly mastering new skills.
Overview
3
3
years of professional experience
Work History
Automation Specialist
Tyrion Integration
Midland, TX
08.2024 - Current
Monitored automated processes, identified issues and took corrective actions as necessary.
Finished projects on time and within budget.
Built panel boxes
Troubleshot Emerson gateways.
Troubleshot Signalfires
Troubleshot wireless pts.
Built programs in Node-Red
Made adjustments in Allen-Bradley PLCs.
Installed, configured, maintained and upgraded Linux operating systems and services.
Integrated various communication protocols into new or existing control systems such as Ethernet, IP, Modbus TCP, IP, Profibus .
Know how to troubleshoot
Configured network connections between multiple devices used in an automated system setup.
Automation Technician
EOG
Midland, TX
07.2023 - 08.2024
Calibrated sensors and other components used in automated systems to optimize accuracy and reliability
(Vega ultrasonic radars and containment fill alarms)
Repaired malfunctioning motors, valves, actuators, pumps., as needed
(Valvecons, Beis control valves.)
Troubleshot and resolved issues with automated systems, including mechanical, electrical, and software components
(Analog & Modbus components)( Scadapac PLCs)( Maple & Red Lion HMIs.)
Followed design specifications when installing wiring and other electrical components to complete, upgrade, or repair systems
(Reuse pit panels, recirculation skids, chemical skids and spill prevention units, and d-fits.)
Measured voltage, resistance and current of electrical circuits to assess operating conditions and identify faults
Removed and replaced malfunctioning circuit boards and sensors
Performed preventive maintenance on automated systems and equipment to ensure optimal performance
Created detailed documentation for automation processes and procedures
Implemented safety protocols related to automated systems operations in accordance with OSHA standards
Trained operators on how to use automated equipment safely and effectively
Managed, troubleshot and improved automation programs
Diagnosed, fixed and optimized electrical control systems
Delivered advanced troubleshooting support for maintenance team
Communicated automation test results to team members and highlighted potential risks
Developed technical solutions to resolved complex range of problems
Measured voltage, resistance and current of electrical circuits to assess operating conditions and identify faults
Removed and replaced malfunctioning circuit boards and sensors
Removed, replaced and calibrated pressure and temperature Rosemount Transmiers
Have performed many Point to Points with SCADA on Oil, Gas ands Water Skids
Have Simulated triggering alarms on Oil Lacts during Point to Point with Scada
Have Programmed process flow computers such as Roc 800s, TotalFlow G5 XFC, Totalflow G5 UFLO, TotalFlow G5 XRC
Have Programmed Allen Bradley Micrologix and Compact Logix
Have Replaced and programmed Allen Bradley PanelViews and Red Lion HMIs
Have calibrated Static Pressure, Differential Pressure and Temperature components on Gas meter Total-flows
Have troubleshot, removed and replaced PowerFlex 753 Variable Frequency Drives and also Eaton
Have ran conduit to run wires and cat5 in
Have mounted, set up and calibrated AMI O2 Analyzers
Have Calibrated instruments and Analog Inputs using Process meters
Have ran, bent and cut Stainless Steel tubing
Have Troubleshot, repaired and installed Actuators for control valves
Automation Technician
Central Texas Automation And Control Services LLC
Hobbs, NM
04.2022 - 06.2023
Removed, replaced and calibrated pressure and temperature Rosemount Transmiers
Have performed many Point to Points with SCADA on Oil, Gas ands Water Skids
Have Simulated triggering alarms on Oil Lacts during Point to Point with Scada
Have Programmed process flow computers such as Roc 800s, TotalFlow G5 XFC, Totalflow G5 UFLO, TotalFlow G5 XRC
Have Programmed Allen Bradley Micrologix and Compact Logix
Have Replaced and programmed Allen Bradley PanelViews and Red Lion HMIs
Have calibrated Static Pressure, Differential Pressure and Temperature components on Gas meter Total-flows
Have troubleshot, removed and replaced PowerFlex 753 Variable Frequency Drives and also Eaton VFDs
Have ran cat5e, made RJ45 connection ends
Have set up cradlepoints cell modems
Have ran conduit to run wires and cat5 in
Have mounted, set up and calibrated AMI O2 Analyzers
Have Calibrated instruments and Analog Inputs using Process meters
Have ran, bent and cut Stainless Steel tubing
Have Troubleshot, repaired and installed Actuators for control valves