With extensive experience in electrical troubleshooting, conduit bending, and circuit installation.
Proven ability to manage complex projects, ensuring safety and compliance.
Willing to work extras hours and weekends
Able to travel
Overview
2
2
Languages
1
1
Certification
20
20
years of professional experience
Work History
Journeyman Electrician #232941
Bechtel
Brownsville, TX
05.2026 - Current
RGLNG Project.
Mostly raceways, cable trays channel trays.
Wire Pulls
Meg wire on the spools before running cable just in case they were damage by forklift or somewhere on the way to the plant.
Terminated transformers and Switch Gears
Terminating the cables from some MCC switch gears on the north side to the MCC switch gear going to the south.
Journeyman Electrician #232941
Bluewater Energy
Tatum, TX
10.2025 - 03.2026
Martin Lake Plant
This was a Shout Down
Some cables were burned so we had to Meg every cable going to Disconnect, Transformer, Motors Etc.
Cables that were damage we would report to get what ever cables were damage re ran
Phoned out new cables Meg them then terminated them with labels and torque every bolts on switch gears and transformers.
Took pictures to every megging and termination that was complete and share in on the XForm that the company gave us to turn in to them
Journeyman Electrician
MMR Procom
Port Sulphur, LA
06.2024 - 09.2025
Plaquemine LNG Plant
Here at the substations and MCC we did a Point to point and also the Red Lines at the Switch Gears.
Meg, Ductor the bus bars on the Switch Gears and Breakers.
Did the test for CTs and PTs
VLF test the cables at 21kv after the stress cone were completed from Switch Gears to Transformers
Transformer Testing and Oil Samples
Batteries Discharge Testing with a small load bank to test if their was any defected batteries just in case their was a shortage on the 125VDC the batteries should keep them running
Journeyman Electrician #232941
Deep South Electrical Contractors
Edinburg, TX
09.2023 - 04.2024
Worked at a Coil Heat Exchanger Plant in Toledo, Ohio
Was a Supervisor at this job.
Installed temporary 120/208 pedestals that were fred from temporary rental generators
Had to maintenance the Generators make sure they were always on and running. Had a crew running in days and another crew for nights
Journeyman Electrician #232941
JBI Electrical Systems Inc.
Fort Worth, TX
02.2021 - 03.2023
Installed 3 big Generators and a ATS at the back of every Walmart in Texas
Ran cables in PVC conduit then terminated the generators and ATS
Installed a temporary Generator that fed the walmart while we had to shut off the main power source but before that we would check for rotation. Then we would reroute the conduit from the Transformer going to the MDP because now we had to install the ATS in between them.
after re routing the conduit we ran new cable going from the Transformer to the new ATS and to the MDP
Terminated all the cables in ATS and MDP, the Utility Company of each town would terminate the Transformer side.
After everything was back on and we had our 277/480 voltage we would test for rotation then start Walmart's back to normal.
Became a Supervisor for the underground conduit
Journeyman Electrician #232941
Traid Electric and Controls
Texas City, TX
10.2019 - 03.2021
Air Products Texas City
Started off as a terminator
Phoned out cables going from motor to MCC
Tailed in cables from the bottom of the MCC gland them then terminate them in their proper breaker
Gland on the motor side and terminated installed labels
Phoned out cables from the MCC to receptacles and light fixtures
Gland receptacles and light fixtures with labels
Gland and terminated on the panel side
Did very little Stress Cones
Journeyman Electrician #232941
MMR Contractors
Port Lavaca, Tx
12.2019 - 08.2020
Formosa Plant
Installed cable trays, channel tray.
Fabricated channel tray, installed supports
Used the hydraulic bender for bending the ridgid conduit
Used the power pony and treader machine to do the treads on the conduit
Journeyman Electrician #232941
MMR Procom
Macon, GA
06.2019 - 10.2019
Fleenor Paper CO.
Started as a Technician got sent to complete a punch list
Mostly trouble shooting looking for cables that were not ran to device or Panels but where claimed as ran.
Found a lot of cables were not ran to the proper location
After we had the cable going from the panel to device we then phoned out cables
Gland and terminated all device that werent ever finished manege finish and complete them
Journeyman Electrician #232941
Zachary Industrial
Beaumont, TX
08.2017 - 02.2019
ExxonMobil Polyethylene Plant
Installed cable tray, channel tray, 2" conduit.
Installed supports and tubing for interments
Also installed and terminated Heat Trace
Leran to read and understand schematic
Phone out cables then Meg them at 500V
Gland cables then terminated them at the Fan Motor and Pump
Gland the cables at the MCC and terminated to its proper location
Journeyman Electrician #232941
Excel
Beaumont, TX
06.2015 - 02.2017
Med Gas Plant
Pulled cable, Installed cable tray and channel tray
Gland cables and terminated devices
Installed ridgid conduit
Journeyman Electrician #232941
G&S Electric
Dallas, TX
03.2011 - 05.2015
Worked at the DFW airport
Remolded Terminal E. Demolished fixtures, conduit, transformers, switch gears.
Reinstalled conduit, ran new cable, installed panel board, transformers, and a switch gear.
Installed a luggage carousel. Ran the conduit wire, and terminated the motors, start stops, limit switches, photocells, etc.
Became a Foreman and work on Starbuck and a Sound Balance from the ground and up their at the DFW Airport which was an added on
Journeyman Electrician
Metro Electric
Elsa, TX
07.2006 - 03.2011
First time every stepping on to the electrical field with zero experience.
Installed electrical systems in commercial buildings, ensuring compliance with local codes.
Diagnosed and repaired electrical issues trouble shooting, enhancing system performance and safety.
Worked under ground ran conduit. Work with EMT conduit ran cable.
Conducted routine maintenance on electrical equipment, reducing downtime and improving reliability.
Installed and Terminated Switch Gears, Panel Board, Transformers, Generators
Read the Blue Prints and Wire Diagrams
Worked with them for 4 years took my Journey Electrical state license and became a Journeyman
Journeyman Electrician #232941
Electic Inc.
Royse City, TX
04.2010 - 01.2011
Here we remolded High Schools
Demoded light fixtures, old panel boards and receptacles
Installed new light fixtures, panel board receptacles, EMT conduit and ran run cable
Installed Smart Electrical Panels and ran Cat6 Cable and terminated
Building Maintenance, Journeyman Electrician, and Supervising Electrician at StratacacheBuilding Maintenance, Journeyman Electrician, and Supervising Electrician at Stratacache