Detail-oriented electrician with extensive experience in cable termination and medium voltage installations. Proven ability to ensure code compliance. Believes in working as a team to get the job done
Overview
8
8
years of professional experience
Work History
Electrican
No Bull Energy
Salome, Arizona
08.2024 - Current
Executed underground installation of auxiliary station transformers, inverters, and batteries.
Installed PVC conduit ranging from 3/4" to 4" for effective electrical management.
Utilized heat box to heat PVC conduit for precise bends.
Constructed and installed conduit racks with uni-strut for secure strapping of conduits.
Terminations
Terminating 350 wires to breakers in switchgear.
Terminating 350 wires in disconnects being fed from switchgear
Terminating 750 wires onto buss bar in switchgear coming from transformers
Medium Voltage Termination
Prepping MV cables on a step-by-step basis to be properly terminated
DC cable and BLA cables for PV
Install DC cables along PV cab lines
Install BLA cables
Prep DC and BLA cables to be terminated into combiner boxes
Electrician
Integrity Electrical Services
Tempe, Arizona
07.2018 - 06.2024
Commercial warehouse ground up projects and TI projects
Ensured compliance with local electrical codes and safety regulations.
Mentored junior electricians on best practices and safety protocols, fostering a culture of safety and compliance.
Utilized hand tools, power tools, and testing equipment daily.
Contributed to planning electrical layouts for new installations and renovations, enhancing project execution.
Installed conduit and wire
Connected wires to circuit breakers, transformers, or other components.
Repaired or replaced worn or defective parts using hand tools and power tools.
Followed safety procedures when working on energized circuits; observed lockout and tagout requirements when servicing equipment.
Installed cables, conductors and completed necessary hook-ups for primary power lines.
Performed electrical installations, maintenance and repairs of electrical systems, wiring, fixtures and components.
Wall rough-in on commercial warehouse projects and TI'S
Underground work installing PVC conduit ranging from 3/4" to 3" in size.
Panel installations for electrical rooms and fire riser rooms. Disconnect installations, landing load/line side in Disconnects
Layouts for overhead fixtures. Chandelier installation.
Conduit installations for new power and lighting
Trace existing circuits for new job of circuits whether it be for power or lighting
Coordinated wire pulling for new power and lighting connections in structures.
cable joint and Termination Technician at China Saudi communication with SECcable joint and Termination Technician at China Saudi communication with SEC