Dynamic Field Service Engineer with proven expertise at Philips Healthcare US in equipment maintenance and technical troubleshooting. Recognized for enhancing customer satisfaction through efficient problem-solving and proactive preventive maintenance. Skilled in system diagnostics and dedicated to safety compliance, fostering team collaboration to achieve operational excellence.
Perform preventive and corrective maintenance, Field Change Orders, and installations on multiple modalities.
Modalities to include: Digital Xray, IGT (Allura products, Azurion), IGTD (Volcano, Intrasight, Mobile Intrasight), Mobile Surgery (BV Pulsera, Veradius Unity, Zenition, and Mobile Diagnost), and Ultrasound (all Philips ULS products)
Program Lead for the US Strategic Weapons System and US Ship Support Program for MOD 6 Fault Isolation Indexes and Procedures. Develop, write, and maintain documentation pertaining to the Fleet Ballistic Missile Systems to include FII/FIT (Fault Isolation Indexes and procedures) and Standard Maintenance Procedures.
Worked in the development of SSGN Standard Maintenance Procedures (SMP’s).
Have a good proficiency in all Windows Office software involved in the performance of these tasks.
Participate in the change control process to ensure all system changes are tracked, updated, and documented appropriately. Familiar with NAVSEA auditing of SUBSAFE equipment and the use of Non Destructive Testing related to Navy submarines.
Acting Process Quality Assurance Representative. Completed our most recent T90001B audit with no discrepancies or deficiencies noted.
Missile Technician First Class (United States NAVY)
Qualified Naval Shipboard Instructor
Served as the shipboard training Petty Officer maintaining the knowledge and qualifications of over 25 Weapons System personnel.
Qualified Small Arms Marksmanship Instructor.
Solely in charge of providing in depth classroom training as well as range qualification testing to more than 120 personnel to maintain our ability to sustain the strategic reaction forces and watch standing capabilities onboard the submarine.
Experienced in preventative and corrective electrical and mechanical maintenance on the following equipment:
3 phase and single phase High Voltage AC power buffering, distribution, and monitoring equipment
Power and monitoring circuits, switches, and fuse boxes
Ammeter, voltmeters, ohmmeters, oscilloscopes, and other test equipment
Alarm systems and other power monitoring equipment
Experienced in reading drawings/blueprints, and schematics for installation of new equipment, additions, and alterations.
Mechanical test/repair of small valves associated with high pressure (4500 PSI) gas and 3000 PSI hydraulic systems.
Experience in radiation control and monitoring- Hazards of Electromagnetic Radiation to Ordnance (HERO).
2004-2006 Divisional Supervisor
Managed and supervised eleven technicians as the Strategic Fire Control Division Leading Petty Officer
Assistant Leading Petty Officer over 25 technicians in the Strategic Weapons Division