Summary
Overview
Work History
Education
Skills
Training
Capabilities
Timeline
Generic

John Armentrout

Morgantown

Summary

Extensive Background in the Energy Sector. Providing Leadership And Support for Our Team

Overview

15
15
years of professional experience

Work History

Control Room Operator

Tenaska Westmoreland Generation Station
12.2019 - Current
  • Controlling the 1055 MW 2X1 Combine Cycle Power Plant which includes: 500KV Switchyard, Water Chemistry, Gas Turbines, Cooling systems, Aux Equipment, Steam Generator, Cems, LOTO, Work Orders, Aux Boiler, Dispatching Gas, Directing Plant Employees to do tasks, Trouble Shooting abnormal situations, creating a Shift Report, Updating Work Orders for Techs to complete, providing reports for Management, training plant staff on the DCS, and providing support for Outages and coverage when needed.
  • Analyzing Data on plant equipment for reliability.
  • Keeping the Plant NERC compliant
  • Improving reliability daily.

Operations- Shift Supervisor/Control Room Operator

Longview Power
02.2017 - 12.2019
  • Controlling total balance of plant including switch yard, switch gear room, turbine generator, boiler, fans, aux boiler, fly ash removal, wet scrubber, air quality areas, CEMS, and cooling water systems.
  • Operating a turbine generator (775MW Super Critical Boiler at 4000 psi)
  • Corresponding with PJM for availability of generation.
  • Corresponding with Dominion for gas nominations.
  • Operating the DCS by analyzing logic and making modifications.
  • Relaying information to immediate managers and teams.
  • Providing guidance and training to junior control room operators, operators, maintenance techs, ICE techs, and contractors.
  • Evaluating and recommending future control room operators through collaboration with management. Writing Evaluations for employees
  • Maintaining records of daily operations.

CRO/ZLD

Panda Power Funds
04.2016 - 02.2017
  • Controlling Zero discharge for the Brine Concentrator from the Control Room of the ZLD
  • Proper lock-out-tag-out on every component in the plant
  • Analyzing water chemistry for the plant
  • Commissioning of every system in the plant for operation
  • Developing procedures for the plant
  • Developing systems description for plant
  • Training Plant Staff on plant equipment and functions (Balance of Plant, Electrical, CT, HRSG, Steam Turbine, Water Chemistry, T-3000).
  • Submitting Bid sheets to Dominion for gas day.
  • Worked with Bechtel Engineers trouble shooting commissioning issues.

Control Room Operator

Longview Power
09.2010 - 04.2016
  • Controlling the total balance of plant including switch yard, switch gear room, turbine generator, boiler, fans, aux boiler, fly ash removal, wet scrubber, air quality areas, CEMS, and cooling water systems.
  • Operating a turbine generator (775MW Super Critical Boiler at 4000 psi) and monitoring ISO phase volts/amps, controlling VAR support for utility needs, & switching of 13.8KV, 4.16 KV and 480 V breakers.
  • Corresponding with PJM for availability of generation.
  • Corresponding with Dominion for gas nominations
  • Operating the DCS by analyzing logic and making modifications.
  • Relaying information to immediate managers and teams.
  • Switching from production power to the 500KV line to the station service transformer during outages, implementing changes to plant equipment (breakers, transformers, motors, pumps, fans, conveyors, air compressors, etc.) based on temperature or pressure trends, ensuring compliance with federal, state & company’s safety and environmental guidelines.
  • Providing guidance and training to junior control room operators, operators, maintenance techs, ICE techs, and contractors.
  • Evaluating and recommending future control room operators through collaboration with management.
  • Conducting several startups and shutdowns on the plant due to on-going commissioning issues.
  • Maintaining records for daily operations.
  • Commissioning several systems prior to the plant going commercial.
  • Commissioned 2 different DCS systems. (T-3000 and Ovation)
  • Filled in as Shift Supervisor as needed

Education

High School Diploma -

Keyser High School
Keyser, West Virginia
06.1997

Gen. Ed. Major

Allegany Community College
Cumberland, Maryland
01.1998

Skills

  • Commissioning Experience
  • Leadership Skills
  • Extensive Maintenance Background
  • Excellent Communication Skills
  • Mentoring
  • Adaptability

Training

  • First Class Maryland Stationary Engineer License
  • Siemen’s Verio Training
  • Foster Wheeler Verio Training
  • Red Tag Pro for tagging out equipment
  • Maximo + Earn for work orders
  • DCS – T3000, Netmation and Ovation Control Logic
  • Utilizing several computer programs
  • Method 9 Training
  • Siemens SGT6 5000F Certificate
  • Siemens SGT6 Certificate
  • Siemens Simulator Training with a Certificate for SGT 5000 F (EE)
  • FAT with Emerson for conversion from T-3000 to Ovation
  • Commissioning Experience
  • NFPA Compliances

Capabilities

Dedicated to do whatever is necessary to create a safe, productive, and positive working environment that supports proper training and growth to all employees.

Timeline

Control Room Operator

Tenaska Westmoreland Generation Station
12.2019 - Current

Operations- Shift Supervisor/Control Room Operator

Longview Power
02.2017 - 12.2019

CRO/ZLD

Panda Power Funds
04.2016 - 02.2017

Control Room Operator

Longview Power
09.2010 - 04.2016

Gen. Ed. Major

Allegany Community College

High School Diploma -

Keyser High School