Years of experience performing electrical maintenance duties and using multiple electrical test equipment. Experience working as a individual contributor and working with a team.
Overview
17
17
years of professional experience
7
7
years of post-secondary education
Work History
CBM Specialist Sr.
Plant Scherer
4 2023 - Current
Self-starter who works independently
Strong organization and analytical skills
Collaborated with cross-functional teams to achieve project goals on time and within budget
Organize and schedule monthly CBM routes to perform motor online and offline testing.
Work with wide range of electrical test equipment and tools.
Test Motors using PDMA MCEmax Tester
Effectively demonstrate Southern Style behaviors
Communicate with multiple work groups including covered employees, contractors, engineers, system owners, and plant leadership.
Use Microsoft Office products (Word, TEAMS, Excel, etc).
Use CBM data to make recommendations for plant equipment maintenance.
Utilized Lock-Out Tag-Out (LOTO) process to safely test plant equipment.
Use Maximo processes, including CBM routes, Maintenance Strategy and equipment data, and purchasing applications.
Analyze and trend data for the purpose of determining recommended maintenance actions, current condition of equipment, and failure analysis.
Coordinate shipment and return for motors refurbishment and rewinds
Maintain relationship with Forest Park Repair Shop to gather and analyze acceptance data on new/rebuilt equipment.
Available for CBM on-call duties per on-call schedule
Protection and Control Services Technician III
Georgia Power
05.2022 - 04.2023
Perform routines for substation testing, ensuring they are completed without service interruptions.
Self-motivated and work independently.
Communicate with multiple work groups including customers, covered employees, engineers, and leadership.
Use Microsoft Office products (Word, TEAMS, Excel, etc).
Work with wide range of electrical test equipment.
Troubleshooting low battery, low voltage, loss of voltage alarms in substations control house.
Test relays and current transformers using Meggar, Omicron CT Analyzer, Doble, Power DB software, Schweitzer AcSELerator software, and Protection Suite software.
Commission, test, maintain, and trouble shoot protective relaying, controls, and communication equipment associated with substations and transmission power lines.
Read and use one line, three line, and elementary electrical prints.
Manage clearances effectively to meet quality, schedule, and budget targets.
Coordinate substation outages and commissioning activities with multiple internal and external stakeholders.
Perform in-depth electrical acceptance testing of relays.
Supervise construction and pre-commissioning of electrical control house and substations.
Mentor co-op engineers and new hires in job-specific tasks.
Prepare technical documentation for testing, troubleshooting, and maintenance of substations.
Maintained a safe work environment by strictly adhering to established safety protocols and guidelines
Electrician
Georgia Power (Plant Scherer)
11.2017 - 05.2022
Utilized Lock-Out Tag-Out (LOTO) process to safely work on plant equipment.
Troubleshoot and repaired plant electrical equipment.
Perform plant monthly Battery PM
Read and followed procedures of electrical blueprints.
Analyzed electrical circuits, performed electrical/electronic testing and calibration.
Utilized computer based maintenance management system (Maximo).
Performed maintenance on motors, contollers, switchgear, relays, transformers, generators, and AC/DC systems.
Tested electrical systems functionality and continuity of circuits using devices such as ohmmeters, voltmeters, amprobe, and meggers
Utilized experience in electronics, instrumentation, and PLCs.
Assessed electrical systems, equipment and components to identify hazards, defects and needed adjustments or repairs.
Apprentice/Meter Technician A
Georgia Power
09.2011 - 11.2017
Self-motivated and worked independently.
Created daily schedule to ensure meters within due dates.
Communicated with multiple work groups including customers, engineers, and leadership.
Installed transformer-rated metering systems, including sizing instrument transformers, determining multipliers, programming solid-state meters, and the wiring and maintenance of all types of single and three phase transformer-rated installations.
Performed field test on all types of self-contained and transformer-rated mechanical and electronic meters, including the use of the dead-front test jack, testing with a single standard and phantom load, and testing using customer load with newer technology test equipment.
Used multiple test equipment including PowerMite, PowerMate, and PowerMaster meter tester.
Installed and programmed multifunction meters, hands-on design, wiring, testing, and troubleshoot multicircuit, multifunction metering systems.
Worked assigned storm duty, which included evenings, weekends, holidays, and overnight travel.
Apprentice Electrician
Georgia Power ( Plant Mitchell/Repair Shop)
02.2008 - 09.2011
Worked under supervision of Journeyman Electrician to learn trade and develop electrical knowledge.
Tested continuity of circuits using test equipment to verify compatibility and safety of systems following installation, replacement or repair.
Tested electrical systems functionality and continuity of circuits using devices such as ohmmeters and voltmeters.
Assessed electrical systems, equipment and components to identify hazards, defects and needed adjustments or repairs.
Read and followed procedures of electrical drawings/prints.
Analyzed electrical circuits, performed electrical/electronic testing and calibration.
Utilized computer-based maintenance management system (Maximo).
Utilized basic experience in electronics, instrumentation, and PLCs.