Explored diverse areas within the electrical field to broaden technical
Promoted to CEMS technician on 12/30/2025 Responsibilities: Calibrating, maintaining and troubleshooting Constant Emissions Monitoring System. Industrial manufacturing maintenance and troubleshooting, 24 Volt, 120 Volt, 230 Volt, 480 Volt and 4,160 Volt AC systems, DC control systems, motor starters, fuses, transformers, solenoids, limit switches, photo eyes, proximity switches, induction motors, feeders, HMI's and VFD's using electrical schematic's. Installation of industrial wiring, used megohm-meters to diagnose faults and multi-meters for checking current voltage and resistance. Repaired and installed lighting systems, wall receptacles and welding receptacles. Troubleshoot PLC based control systems, including diagnosing faults in input and output modules, fabricated junction boxes for field wiring. Motor replacement included termination of motor leads from ½ HP up to 400 HP motors. Troubleshot, repaired, and replaced instruments such as pressure transmitters, thermal transmitters, flow transmitters, thermocouples, RTDs, radar level, encoders, beck valve, and load cells.
Promoted to Night-shift lead 8/19/24
Provides information needed for safety meetings for the team, fill out lock out paperwork, oversee night shift electrical projects, train other technicians, Industrial manufacturing maintenance and troubleshooting, including 24 Volt, 120 Volt, 230 Volt, and 480 Volt AC systems, DC control systems, motor starters, fuses, transformers, solenoids, limit switches, photo eyes, proximity switches, induction motors, synchronous motors, feeders, temposonic rods, HMI's and VFD's.Installation of industrial wiring, used megohmmeters to diagnose faults and multi-meters for checking current voltage and resistance.Repaired and installed lighting systems, wall receptacles and welding receptacles.
Troubleshoot PLC based control systems, including diagnosing faults in input and output modules, fabricated junction boxes for field wiring.
Motor replacement included termination of motor leads from ½ hp up to 400 hp motors.
Verified and troubleshot production process issues using Allen Bradley PLC programming devices (PC's). Use Comact systems and program to help aid in troubleshooting process.
Industrial manufacturing maintenance and troubleshooting, including 24 Volt, 120 Volt, 230 Volt, 480 Volt, 2,300 Volt and 12,470 Volt AC systems, DC control systems, motor starters, fuses, transformers, solenoids, limit switches, photo eyes, proximity switches, induction motors, synchronous motors, feeders, HMI's and VFD's. Installation of industrial wiring, used megohm-meters to diagnose faults and multi-meters for checking current voltage and resistance. Repaired and installed lighting systems, wall receptacles and welding receptacles.
Troubleshoot PLC based control systems, including diagnosing faults in input and output modules, fabricated junction boxes for field wiring. Motor replacement included termination of motor leads from ½ hp up to 550 hp motors. Involved in maintenance of exciters on generators and synchronous motors. Verified and troubleshot production process issues using Allen Bradley and Modicon PLC programming devices (PC's).
Reason for leaving: Plant Closure
Installed marine electronics and a variety of electrical devices on newly manufactured boats, operated forklifts, applied and repaired fiberglass and gelcoat, hung and installed large outboard motors and jack plates; installed and wired consoles, leaning posts, T-Tops and hard tops.
Reason for leaving: Better job opportunity
Troubleshot and repaired industrial controls that included contactors, proximity switch cables, electromechanical relays, installed conduit.
Installed gear drive chains, gears, pulleys, pulley belts, conveyer belts, hydraulic cylinders, air valves, and brake cylinders.
Certified to operate forklift, genie boom and load-all.
Safety training included fall protection, acid training, surface mining safety, and proper PPE protection.
Troubleshot, removed and replaced 3 phase motors up to 20 HP.