Lead Technician supporting commercial and industrial equipment uptime through troubleshooting, calibration, preventive maintenance, and repair documentation. Diagnoses faults with multimeters, Megger, thermal cameras, and injection test tools, then restores equipment to manufacturer specifications. Coordinates repairs, safety practices, and apprentice guidance to keep service work on schedule.
Partnered with engineering teams to implement strategic system improvements and upgrades.
Analyzed service data to create detailed reports, outlining findings and recommending necessary corrective measures.
Developed detailed service reports, documenting findings and recommending corrective actions.
Performed the necessary Acceptance Testing for electrical equipment within Data Center Facilities.
Familiarity with commissioning software, PLC communications and MOXA devices and changing IP addresses for devices, ATS and SEL software and electrical testing tools such as multimeters and insulation resistance testers.
Demonstrated expertise in industry-specific electrical code regulations and safety standards, including OSHA and NFPA 70E compliance.
Conducted thorough troubleshooting of switchgear maintenance and facilitated efficient breaker installations to ensure operational reliability.
Strong electrical aptitude, understanding of power systems and problem-solving skills.
Applied comprehensive knowledge of LDL, L2, L3, L4, and L5 inspections to ensure compliance and quality assurance.
Specialized in testing and verifying secondary injection protocols for breakers, alongside installation of PT/CT wiring to enhance system performance.
Analyzed and implemented bus installations, focusing on accurate meter configurations and effective control wiring solutions.
Achieved compliance with safety regulations through effective management of permit to work (PTW) and lock out - tag out (LOTO) duties. Proactively maintained ARC flash safety certification to minimize risk as well as secured 40 CAL certification to enhance electrical safety measures.
Ability to read and interpret electrical drawings and schematics.
Hands-on experience with testing and maintenance tools (multimeters, megohmmeters, etc.).
Lead Technician
1 Year 2 Months
A.B.M. | Tempe, AZ | 08.2022 - 10.2023
Utilized a variety of hand tools including soldering irons, screwdrivers, pliers, cutters, wire strippers and crimpers.
Utilized specialized diagnostic tools to efficiently identify system faults.
Maintained records of repairs, calibrations, and tests performed on equipment.
Performed troubleshooting and repair of equipment in accordance with manufacturer specifications.
Reviewed technical manuals and other documents related to product operation and maintenance requirements.
Tested and calibrated instruments to ensure accuracy and reliability of data.
Diagnosed problems using test equipment such as multimeters, Ductor, Thermo Camera,Megger, power supplies,T.T.R, Primary and Secondary injection
Replaced defective components or parts to ensure optimal functionality.
Conducted preventive maintenance procedures according to established schedules.
Managed quality control and maintained high level of customer satisfaction.
Participated in training to maintain technical expertise and proficiency on applicable equipment.
Followed safety practices to safeguard against injury and damage to property.
Utilized hand tools to properly splice cables.
Executed scheduled appointments punctually to ensure consistent quality service.
Installed new components or replaced defective parts to restore functionality.
Troubleshot malfunctions and diagnosed issues to service equipment quickly and fully.
Adjusted, connected, or disconnected wiring, piping and tubing to complete repairs and installations.
Inspected materials and equipment regularly to check for potential hazards and machine defects.
Followed safety guidelines and wore protective gear when using power drills, circular saws, and other power tools.
Coordinated repair and maintenance plans with co-workers and supervisors ahead of scheduled projects.
Communicated with distributors to acquire necessary equipment for projects.
Ran tests on newly repaired machinery and equipment to confirm proper functionality.
Journeyman Electrician
11 Months
Catapult Staffing | PLANO , TX | 09.2021 - 08.2022
Kept work areas clean, neat and free of hazards.
Performed rough-in, termination and underground work.
Installed conduit, wire and motor controls.
Traced and diagnosed electrical malfunctions using hand tools and test equipment.
Interpreted schematics, blueprints and diagrams to complete projects on time.
Adhered to specifications and codes in installation of electrical wiring, equipment and fixtures.
Directed electricians on installation, maintenance and repair on electrical wiring and equipment.
Evaluated electrical systems, equipment and components to identify and resolve defects and safety risks.
Reported improper conduct and events to maintain safe working environment.
Electrician
7 Years 4 Months
Hawkeye | Chandler, AZ | 05.2014 - 09.2021
Installed conduit, wire and motor controls.
Connected wires to circuit breakers and transformers.
Traced and diagnosed electrical malfunctions using hand tools and test equipment.
Interpreted schematics, blueprints and diagrams to complete projects on time.
Adhered to specifications and codes in installation of electrical wiring, equipment and fixtures.
Directed electricians on installation, maintenance and repair on electrical wiring and equipment.
Assessed, tested and operated variety of electrical components and systems.
Worked extensively on three-phase, 277/480 volt power distribution systems.
Planned and installed complicated circuit systems in both commercial and residential construction.
Placed and installed safety systems and set up emergency lighting, uninterruptible power systems and battery systems.
Identified and addressed hazards, defects and repair requirements through inspection of electrical equipment.
Tested entire electrical assembly for performance levels and safety concerns.
Responded to emergency callbacks and provided onsite support.
Reviewed and assessed electrical, mechanical, and architectural diagrams and specifications to accurately complete projects.
Selected equipment and fixtures to draft wiring layouts and develop plans for installation according to project specifications.
Reported improper conduct and events to maintain safe working environment.