Terminated and commissioned 120/240V and 277/480V panels in commercial, warehouse, and data center environments with zero safety incidents.
Led conduit and power distribution installations for multiple school construction projects, consistently passing inspections and completing ahead of schedule.
Installed and wired over 500 high-bay and pole lighting fixtures, improving facility efficiency and reliability.
Successfully installed utility meter bases and emergency panels, ensuring uninterrupted power for critical facilities.
Operated mini excavator and ran underground 4-inch PVC conduit, reducing subcontractor costs and supporting project timelines.
Assisted in data center commissioning and testing, contributing to uninterrupted uptime for mission-critical systems.
Trained and mentored apprentices and junior electricians on NEC-compliant terminations, wiring, and safety practices.
Troubleshot and repaired lighting and power issues, reducing downtime for schools, warehouses, and commercial clients.
Implemented organized labeling, testing, and load-balancing procedures for panels, improving safety and operational reliability.
Overview
6
6
years of professional experience
Work History
Electrical Quality Control Specialist
CEC Facilities Group
Irving, TX
09.2024 - Current
Conducted routine inspections to ensure compliance with quality standards and safety regulations.
Collaborated with cross-functional teams to identify and resolve quality-related issues effectively.
Assisted in developing and implementing quality control procedures to enhance operational efficiency.
Developed comprehensive reports detailing findings, recommendations, and corrective actions taken.
Inspected finished goods to verify conformance with customer specifications and company quality standards.
Reviewed technical documents such as specifications and drawings, maintaining accuracy and compliance with industry regulations.
Educated employees on specific QA standards and confirmed maintenance of standards.
Completed supporting documentation for testing procedures, data capture forms, equipment logbooks and inventory forms.
Electrical Terminator
CEC Facilities Group
Irving, TX
09.2024 - Current
Worked flexible hours across night, weekend, and holiday shifts.
Passionate about learning and committed to continual improvement.
Led termination of electrical distribution equipment in a large-scale data center environment.
Installed and terminated power cables for switchgear, panelboards, transformers, UPS systems, and HVAC equipment
Interpreted electrical blueprints, single-line diagrams, and panel schedules to ensure accurate connections.
Performed torqueing, labeling, and phase identification per manufacturer specifications and NEC standards.
Conducted continuity testing, megger testing, and assisted with energization and commissioning.
Coordinated with project managers, inspectors, and other trades to maintain schedule and quality standards.
Ensured compliance with safety protocols, lockout/tagout procedures, and job site regulations.
Supervised crew members and verified workmanship met data center reliability standards.
Electrician
Avid
Roanoke, TX
01.2021 - 08.2024
Installed, distributed, and terminated power from 120/240V single-phase and 277/480V three-phase panelboards.
Routed and installed feeders and branch circuits in commercial and warehouse environments.
Installed and supported utility meter bases; coordinated service connections from utility power sources.
installed up to 3-inch EMT conduit including overhead and wall mounted runs
Installed and wired over 500 high-bay lights in warehouse ceilings, ensuring proper circuit loading and support.
Performed installation, troubleshooting, and commissioning of lighting control systems.
Interpreted electrical drawings, panel schedules, and load calculations to ensure code-compliant installations.
Followed NEC standards, safety procedures, and lockout/tagout protocols on active job sites.
Electrician Top Helper
CMS Mechanical Services
Denton, TX
01.2022 - 01.2023
Performed electrical installations for new school construction and facility expansions.
Installed and routed EMT conduit systems from panelboards to branch circuits throughout classrooms, offices, and common areas.
Distributed power from standard and emergency panels in compliance with NEC and project specifications.
Installed and mounted interior and exterior lighting systems, including wall packs and building-mounted fixtures.
Installed and wired exterior pole lighting systems.
Ran 4-inch PVC conduit in underground and crawl space environments for feeder and branch circuits.
Operated mini excavator to trench for underground conduit runs.
Pulled and terminated feeders to standalone electrical rooms not attached to the main facility.
Performed electrical work in elevator crawl spaces and mechanical areas, maintaining strict safety standards.
Coordinated with inspectors and other trades to ensure timely, code-compliant installations.
Apprentice Electrician
K Electric
Dallas, TX
11.2019 - 01.2021
Installed MC cable and supported branch circuit wiring in commercial environments.
Mounted and terminated 4-square junction boxes; performed splicing and proper joint connections.
Removed and replaced interior lighting fixtures during remodel and upgrade projects.
Installed and wired exit signs and emergency lighting systems.
Wired duplex and quad receptacles in accordance with NEC standards.
Installed and terminated single-pole and multi-way switches.
Assisted licensed electricians with troubleshooting and service calls.
Maintained job site safety standards and ensured code-compliant installations.
Crew Management/foreman/ Quality Control at Minnesota Landscaping and Habitat.Crew Management/foreman/ Quality Control at Minnesota Landscaping and Habitat.