Detail-oriented team player with strong organizational skills. Ability to handle multiple projects simultaneously with a high degree of accuracy. To seek and maintain full-time position that offers professional challenges utilizing interpersonal skills, excellent time management and problem-solving skills.
Terminate / install service conductors 750 mcm
Install filters for energy sign harmonics
Work directly with UL listing equipment
Government Facility data center install Halo
Clean Firewall secure area level 3 Aligned data center
CPR certification
Hydraulic bender 881 qualified operator
Meg conductors
QAQC
One line proficient review
Shut Down team facilitator
Alhambra detention complex Van Buren buildings
1-9
Install underground vaults for site
Coordinate prison level precision rough in block
Install duct bank for feeder trunks 12-14' below grade
Lead rough in for backup power and terminations team
Coordinate with HVAC , Fire, Plumbing, block all conflict/clash
Submit RFIs for change orders
Track Footage and racking per Details engineered by architect
Submit dailies for progress and restraints
Managing Large - small project start to finish
Troubleshooting electrical issues
Conduit bending formulas and calculations
Ordering materials
QAQC
Coordinating installation per scope outline
Documenting site conditions and changes
Code book and code change adoptions
Derating sizing conductors for pipe fill, box fill, distance/ voltage drop AC and DC
GROUNDING and Bonding
Service entrance Provisions
Backup power transfer switches and fire pumps
Fire Alarm system install and troubleshoot
Emergency systems and Life safety systems