A Tech/Installer position that will utilize my 27 years of telecommunications installation experience.
Thorough team contributor with strong organizational capabilities. Experienced in handling numerous projects at once while ensuring accuracy. Effective at prioritizing tasks and meeting deadlines.
Work History
TECH IV INSTALLER
4 Years 8 Months
CBM of America | 10.2021 - 06.2026
Installed telecommunication systems in Google Data Centers/CCNR/Server hall, and ila's. Ciena GLS 6500 R-4/14 Slot, Nokia R-5/1830 psi, Precombiner, MXN, Juniper Switch, Hydra console patch panel, (FSM) Fiber shuffle module, Waveserver, and FMT.
Troubleshot technical issues with OSP/jumpers/MPO fibers to ensure minimal downtime and uninterrupted service delivery.
Documented and reported technical processes and resolutions to maintain accurate records.
Delivered exemplary customer service by addressing client inquiries and resolving issues promptly.
Conducted system (local) configuration/Bootstrap using Puddy to validate functionality of the Network element.
Collaborated with my installation manager, Google Engineers and Google NOC to achieve project objectives and improve workflow.
DC Power Technician
4 Years 7 Months
C4 Technical Solutions | 01.2015 - 08.2019
EMPLOYMENT HISTORY Tech 4 Installer, Pittsburgh, PA
Ran/connected cables to Alcatel- DACS IV, DACS III, LGX Shelves (ADC/Lucent), EIB, DSX3, DSX1, Sync Timing Bays, Delta- COVP, FSME, FSMB, Node B-(3G Network), GSM/GSM2-(2G Network), Henry Fuse Panels (PDP, LVD) BDFB, MDF, Return & Ground Buses
Performed wire-wrapping (22, 24, 26 AWG), auxiliary framing/iron work, Layout and mounting of bays/frame, top-support in various earthquake zones (Levels 1-4) using seismic anchors/auxiliary bracing, securing cables to the standards of the AT&T TP76300
Ran/connected main ground, cross aisle ground, aisle grounds, and frame ground
Performed fire-stopping on cable holes between floors and walls (Hilti/3M)
Built fiber protection system for east and west runs-Norton/ADC Panduit
Ran/connected various fibers/risers fiber-SM/MM (SC, LC, FC, ST connectors)
Ran/connected power cables (750, 500, 350, 4/0, 2/0, 1/0, 12-2 AWG, (in-line taps as well as H taps)
Experienced in crimping lugs/BNCs- ADC/King heads
Ran/connected LANs, CITs, Fuse Alarm, Power Alarm, and Bay Alarm cables
Slot and seated cards using (ESD) strap.
Installer I
5 Years
TekSystems | 01.1999 - 01.2004
Voice and data cabling to patch panel
Punch downs on 66, 110 block
Crimped RJ45 Connectors using color code
TOOLS USED Hilti Hammer drill/Cordless Drill TBM14M hydraulic crimpers P-Touch and Brady Labeler Milwaukee band saw Fiber test kit, WestOver Fiber Grading Kit Coaxial stripping kit Standard pneumatic wire-wrap gun Burndy manual crimpers Fip 500 fiber scope Power meter for DB loss
Education
High School Diploma
Boyd County High School | Boyd County, KY | 06-1998